<!-- Add the related story/sub-task/bug number, like Resolves #123, or remove if NA --> **Related issue:** NA ## What & why Two independent defects in the default MSI scripts. Neither has any server-side handling, so the script text is the only place either can be fixed. ### 1. Reboot-required exit codes reported as install failures The default MSI install script (`pkg/file/scripts/install_msi.ps1`) ended with `Exit $installProcess.ExitCode`, passing msiexec's raw exit code straight through. An install that **succeeded but requested a reboot** therefore reported as a failed install: - `3010` — `ERROR_SUCCESS_REBOOT_REQUIRED` - `1641` — `ERROR_SUCCESS_REBOOT_INITIATED` Both default MSI *uninstall* scripts (`uninstall_msi.ps1` and `uninstall_msi_with_upgrade_code.ps1`) already carve these out via `$successCodes = @(0, 3010, 1641)` — install was the only MSI script missing it. This change adds the same check, using the identical idiom and comment wording as the uninstall scripts. ### 2. Unquoted log file path in the `/lv` argument The default MSI install and remove scripts passed the log path unquoted: ```powershell -ArgumentList "/quiet /norestart /lv ${logFile} /i `"${env:INSTALLER_PATH}`"" ``` `Start-Process` appends a single-string `-ArgumentList` to the command line verbatim — it adds no quoting of its own. `${env:INSTALLER_PATH}` was already protected by escaped quotes; `${logFile}` was not. So when `TEMP` contains a space, msiexec tokenizes the path on whitespace: `/lv` receives only the chunk up to the first space (`C:\Users\John`), and the remainder (`Smith\AppData\...\fleet-install-software.log`) is left as a stray token, which msiexec rejects as an invalid command line (`1639`). The install fails outright rather than merely writing its log somewhere unexpected. The fix quotes it the way `${env:INSTALLER_PATH}` already was: ```powershell -ArgumentList "/quiet /norestart /lv `"${logFile}`" /i `"${env:INSTALLER_PATH}`"" ``` **On severity:** this is latent under normal fleetd operation. Install scripts inherit `os.Environ()` from orbit (`orbit/pkg/installer/installer.go`), which runs as a LocalSystem service, so `TEMP` is `C:\Windows\TEMP` — no spaces. It bites when the system `TEMP` is redirected to a path containing a space, or when an admin copies the script (Fleet renders it in the UI) and runs it in a user context whose profile name contains a space. Not reproduced on a Windows host; the analysis is from msiexec's whitespace tokenizing, not from an observed failure. The newer hand-written FMA scripts (`mozilla-vpn_install.ps1`, `egnyte_install.ps1`, `vnc-server_install.ps1`, `vnc-viewer_install.ps1`, `agent-ransack_install.ps1`) already used the quoted form. This brings the older ones in line with them. ## Scope `GetInstallScript("msi")` feeds two paths, both fixed by change 1: 1. The default install script for **user-uploaded MSI packages** (`ee/server/service/software_installers.go`). 2. The generated install script for **MSI-based Fleet-maintained apps** (`ee/maintained-apps/ingesters/winget/ingester.go`). Change 2 additionally covers `remove_msi.ps1` (the uninstall script used for packages added before the uninstall feature shipped) and the nine hand-written winget install scripts that still carried the unquoted form: `azure-functions-core-tools`, `bluej`, `crisisgo`, `delinea-connection-manager`, `geogebra-classic`, `google-ads-editor`, `gotomeeting`, `imageglass`, `sourcetree`. Notes: - **FMA outputs are not regenerated here.** `install_script_ref` is content-addressed, and existing `outputs/*/windows.json` files carry both the ref and the script text, so they stay internally consistent. The ingest workflow runs every 4 hours and will roll the refs for MSI-based apps forward on its own. Regenerating them in this PR would produce a huge diff and trigger Windows FMA validation for every MSI app. - Several per-app FMA install scripts exist **only** to add the exit-code carve-out and become redundant once this lands (for example `scribe_install.ps1` from #50341). They are harmless duplicates of the new default and can be removed in follow-up. Per-app scripts that do other work too (e.g. `delinea-connection-manager_install.ps1` forcing `ALLUSERS=1`) still need to keep their own copy — those got the quoting fix instead. - Neither change applies to `uninstall_msi.ps1` or `uninstall_msi_with_upgrade_code.ps1`: they already handle the reboot codes, and they build `-ArgumentList` as an array with no `/lv` argument at all. - `install_exe.ps1` deliberately left alone — EXE installers have no standard exit-code convention, which is why they use per-app scripts. - The per-app example scripts embedded in `articles/` (CrowdStrike, Cloudflare WARP, SentinelOne) are separate copy-paste content and are not touched. # Checklist for submitter - [ ] Changes file added for user-visible changes in `changes/`, `orbit/changes/` or `ee/fleetd-chrome/changes`. See [Changes files](https://github.com/fleetdm/fleet/blob/main/docs/Contributing/guides/committing-changes.md#changes-files) for more information. No changes file is currently in this PR — the earlier one was removed. Both fixes change user-visible install/uninstall outcomes, so one may be warranted before merge. - [x] Input data is properly validated, `SELECT *` is avoided, SQL injection is prevented (using placeholders for values in statements), JS inline code is prevented especially for url redirects, and untrusted data interpolated into shell scripts/commands is validated against shell metacharacters. Change 2 is precisely this: a path interpolated into a command line is now quoted so whitespace can't split it into extra arguments. ## Testing - [x] Added/updated automated tests `pkg/file`'s golden test (`TestGetInstallAndRemoveScript`) covers the script contents; each script and its golden were changed in lockstep, so they remain byte-identical. `go test ./pkg/file/ -run Script` and `go test ./ee/server/service/ -run TestGetInstallScript` pass. Goldens can be regenerated with `go test ./pkg/file/... -update`. - [ ] QA'd all new/changed functionality manually Not QA'd on a Windows host. Change 1 needs an MSI that returns 3010 under Fleet's SYSTEM context to confirm the install now reports success. Change 2 needs an MSI install run with `TEMP` pointed at a path containing a space. <!-- This is an auto-generated comment: release notes by coderabbit.ai --> ## Summary by CodeRabbit * **Bug Fixes** * Improved MSI installation and removal reliability when log-file paths contain spaces. * MSI installations requiring a restart are now recognized as successful. * Standard MSI success and restart-required results are handled consistently while other errors remain available for troubleshooting. * Updated supported application installers to use the more reliable logging behavior. <!-- end of auto-generated comment: release notes by coderabbit.ai -->
10 lines
275 B
PowerShell
10 lines
275 B
PowerShell
$logFile = "${env:TEMP}/fleet-remove-software.log"
|
|
|
|
$removeProcess = Start-Process msiexec.exe `
|
|
-ArgumentList "/quiet /norestart /lv `"${logFile}`" /x `"${env:INSTALLER_PATH}`"" `
|
|
-PassThru -Verb RunAs -Wait
|
|
|
|
Get-Content $logFile -Tail 500
|
|
|
|
exit $removeProcess.ExitCode
|